10XE2013XG15W

Meister Flow Monitor RVM/U-2/13 G 1/2" Range: 3 - 13 l/min water 20°C Version: SS 316Ti Contact: change over (COC) 250V 1.5A 50VA, IP65 minimum load 3va Operating pressure max. 350 bar Temperature max. 100°C


10XM1030OG20S

Flow Monitor RVM/U-1/30 G 3/4" Range: 10 - 30 l/min water 20°C Flow direction top to bottom Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 250 bar Temperature max. 100°C


10XM1030XG25S

Flow Monitor RVM/U-1/30 G 1" Range: 10 - 30 l/min water 20°C Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 250 bar Temperature max. 100°C


10XM1045XG20S

Meister Flow Monitor RVM/U-1/45 G 3/4" Range: 15 - 45 l/min water 20°C Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 250 bar Temperature max. 100°C


10XM1045XG20SKA

Meister Flow Monitor RVM/U-1/45 G 3/4" Range: 15 - 45 l/min water 20°C Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 67, 1 Metre cable, Operating pressure max. 250 bar Temperature max. 100°C


10XM1045XG25S

Flow Monitor RVM/U-1/45 G 1 inch Range: 15 - 45 l/min water 20°C Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 250 bar Temperature max. 100°C


10XM1045XG25SEM

Flow Monitor RVM/U-1/45 G 1 inch Range: 15 - 45 l/min water 20°C Version: brass Contact: normally open (NOC) 250V 2A 60VA, IP 67, with Atex Operating pressure max. 250 bar Customs no.: 9026 10 81 Categorization of the electrical part of the device Ex II 2G Ex mb IIC T6 Gb Ex II 2D Ex tb IIIC T80°C Db Categorization of the mechanical part of the device: Interior of the Flowmeter:Marking: Ex II...


10XM1045XG25W

Flow Monitor RVM/U-1/45 G 1inch Range: 15 - 45 l/min water 20°C Version: brass Contact: change over (COC) 250V 1,5A 50VA, IP 65 Minimum load 3VA Operating pressure max. 250 bar Temperature max. 100°C


10XM1060OG20S

Flow Monitor RVM/U-1/60 G 3/4" Range: 20 - 60 l/min water 20°C Flow direction top to bottom Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 250 bar Temperature max. 100°C


10XM1150OG25S

Flow Monitor RVM/U-1/150 G 1" Range: 60 - 150 l/min water 20°C Flow direction top to bottom Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 250 bar Temperature max. 100°C


10XM1150XG25S

Flow Monitor RVM/U-1/150 G 1" Range: 60 - 150 l/min water 20°C Version: brass Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 250 bar Temperature max. 100°C


10XM20.2XG15S

Meister Flow Monitor RVM/U-2/02 G 1/2" Range: 20 - 210 ml/min water 20°C Version: brass Contact: normally open (NOC) 230V 3A 60VA, IP 65 Operating pressure max. 300 bar Temperature max. 100°C


10XM20.2XG15SI4.0

Meister RVM/U-2/03 G 1/2 Series Float Meter Measuring Range 20 - 210 ml/min, 20 degree C adjusted with flow direction from bottom to top Operating Pressure Max 300 bar Operating Voltage :24V (19..30V) Analog outpt : 4-20 mA and 0-10V Connection :M12 x 1, 5 pol Ip 67, T-20-70 Degrees C Sensor housing Al blue anodized Version Brass Signal 4.0


10XM20.2XG15W

Meister Flow Monitor RVM/U-2/02 G 1/2" Range: 20 - 210 ml/min water 20°C Version: brass Contact: change over (COC) 250V 1,5A 50VA, IP 65 Minimum load 3VA Operating pressure max. 300 bar Temperature max. 100°C


10XM2007XG15S

Meister Flow Monitor RVM/U-2/7 G 1/2" Range: 2 - 7 l/min water 20°C Version: brass Contact: normally open (NOC) 230V 3A 60VA, IP 65 Operating pressure max. 300 bar Temperature max. 100°C 2 Customs no.: 9026 10 81


10XM2007XG15S

10XM2007XG15S Meister RVM/U-2 Series Float Style Flow Monitor for water and other fluids, Measuring Range 2 - 7 l/min, Operating Pressure Max 350 bar Max temperature 20 deg C , 1/2 inch SP connection, normally open contact with DIN connection, Brass


10XM2013XG15W

Meister Flow Monitor RVM/U-2/13 G 1/2" Range: 3 - 13 l/min water 20°C Version: brass Contact: change over (COC) 250V 1.5A 50VA, IP65 minimum load 3va Operating pressure max. 300 bar Temperature max. 100°C


10XM2020XG15S

Meister RVM/U-2 Series Float Style Flow Monitor for water and other fluids, Measuring Range 4 - 20 l/min, 1/2 inch BSP connection, Operating Pressure Max 350 bar Max temperature 100 deg C (Optional 160 deg C), Brass, with din connection


10XM2030XG15S

Meister Flow Monitor RVM/U-2/30 G 1/2" Range: 8 - 30 l/min water 20°C Version: brass Contact: normally open (NOC) 230V 3A 60VA, IP 65 Operating pressure max. 300 bar Temperature max. 100°C, din connection


11XE20.2XG15S

Meister Flow Monitor RVM/U-2/02 G 1/2" Range: 20 - 210 ml/min water 20°C Version: SS 316Ti Contact: normally open (NOC) 230V 3A 60VA, IP 65 Operating pressure max. 350 bar Temperature max. 100°C


11XE20.2XG15W

Meister Flow Monitor RVM/U-2/02 G 1/2" Range: 20 - 210 ml/min water 20°C Version: SS 316Ti Contact: change over (COC) 250V 1,5A 50VA, IP 65 Minimum load 3VA Operating pressure max. 350 bar Temperature max. 100°C


11XE2007XG15S

Meister RVM/U-2/7 Series Float Style Flow Monitor, Measuring Range 2 - 7 l/min, Water service, Operating Pressure Max 350 bar, Max temperature 100 deg C, G1/2 inch connection, normally open contact (NOC) with DIN43650 connection, 316SS


11XE2020XG15S

Meister Flow Monitor RVM/U-2/20 G1/2 Range: 4 - 20 l/min water 20°C Version: SS 316Ti Contact: normally open (NOC) 230V 3A 60VA, IP65 Operating pressure max. 350 bar Temperature max. 100°C DIN 43650


40XYA050XG25SL

Meister Flow Monitor DWM/A-L50 G 1 inch Range: approx. 0,3 - 2,6 m3/h N2 at 300bar abs. 25°C With flow indication Version: SS 316Ti Contact: normally open (NOC) 250V 3A 100VA, IP 65 Operating pressure max. 300 bar Temperature max. 80°C